TERASAKI (XH225NS) 125AMP MCCB
TERASAKI (XH225NS) 125AMP MCCB

TERASAKI (XH225NS) 125AMP MCCB

MOQ : 100 Pieces

TERASAKI (XH225NS) 125AMP MCCB Specification

  • Rated Short Circuit Breaking Current
  • 35kA
  • Phase
  • Three Phase
  • Rated Short Circuit Making Current
  • 70kA
  • Breaking Capacity
  • 35kA at 415V
  • Mechanical Life
  • 10,000 operations
  • Product Type
  • Moulded Case Circuit Breaker (MCCB)
  • Installation Options
  • Panel Mounting
  • Function
  • Overload and Short Circuit Protection
  • Poles Number
  • 3
  • Rated Voltage
  • 415V AC
  • Rated Current
  • 125A
  • Rated Frequency
  • 50/60Hz
  • Curves
  • NS Series Standard Curve
  • Temperature Protection
  • Up to 40°C ambient
  • Weight
  • Approx. 2.3 kg
  • Color
  • Grey
  • Trip Unit Type
  • Thermal-Magnetic
  • Dimensions (W x H x D)
  • 105 mm x 165 mm x 60 mm
  • Frame Size
  • XH225
  • Ambient Temperature Range
  • -5°C to +40°C
  • Rated Insulation Voltage
  • 690V
  • Protection Class
  • IP20
  • Auxiliary Contact Options
  • Available (optional)
  • Terminal Type
  • Box Lug
  • Rated Impulse Withstand Voltage
  • 8kV
  • Standards Compliance
  • IEC 60947-2
  • Mounting Arrangement
  • Fixed Type
 

TERASAKI (XH225NS) 125AMP MCCB Trade Information

  • Minimum Order Quantity
  • 100 Pieces
  • Supply Ability
  • 100 Pieces Per Day
  • Delivery Time
  • 2 Days
  • Sample Available
  • Yes
  • Main Domestic Market
  • All India
 

About TERASAKI (XH225NS) 125AMP MCCB

MCCB stands forA Molded Case Circuit Breaker. It is another type of electrical protection device which is used when load current exceeds the limit of a miniature circuit breaker. The MCCB provides protection against overload, short circuit faults and is also used for switching the circuits.

Advanced Overcurrent Protection

Designed with a thermal-magnetic trip unit, the XH225NS guarantees accurate detection and interruption of overloads and short circuits, preventing damage to wiring and downstream equipment. Its 35kA breaking capacity at 415V AC makes it suitable for demanding power distribution applications requiring superior safety and reliability.


Durable and Versatile Design

The robust build of the XH225NS, featuring a frame size of XH225 and IP20 protection, ensures longevity and reliable performance. The circuit breaker can endure up to 10,000 mechanical operations and operates effectively within a temperature range of -5C to +40C, making it ideal for varied environments.

FAQ's of TERASAKI (XH225NS) 125AMP MCCB:


Q: What are the installation options for the TERASAKI XH225NS MCCB?

A: The XH225NS MCCB is designed for panel mounting, allowing it to be securely installed in electrical panels and switchboards. The box lug terminal type provides straightforward and safe wiring connections.

Q: How does the thermal-magnetic trip unit benefit circuit protection?

A: The thermal-magnetic trip unit ensures prompt detection and interruption of overload and short circuit faults, enhancing system protection. This dual-action mechanism helps prevent electrical fire risks and equipment damage by responding to both prolonged overloads and instant surges.

Q: When should I consider adding an auxiliary contact option?

A: Auxiliary contacts are useful for monitoring or signaling the breaker's status remotely. You should consider adding them if system integration, remote control, or status indication is required in your application setup.

Q: What standards does the TERASAKI XH225NS comply with?

A: The XH225NS MCCB complies with IEC 60947-2 standards, ensuring it meets international safety, performance, and reliability requirements for low-voltage switchgear and controlgear.

Q: Where can the XH225NS MCCB be used effectively?

A: Suitable for industrial, commercial, and infrastructure projects, the XH225NS is ideal for environments demanding high reliability, such as factories, distribution boards, and large office complexes.

Q: What is the rated short circuit breaking capacity and its significance?

A: The XH225NS offers a breaking capacity of 35kA at 415V AC, allowing it to safely interrupt high short-circuit currents. This ensures quick fault isolation, minimizing damage and downtime in the system.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in MCCB(Molded Case Circuit Breaker) Category

SIEMENS MCCB - 100A

SIEMENS MCCB - 100A

Price Range 50.00 - 500.00 INR / Piece

Minimum Order Quantity : 100 Pieces

Rated Current : 100A

Rated Voltage : 415V AC

Weight : Approx. 1.2 kg

Rated Short Circuit Making Current : 50 kA

C&S MCCB 400A

C&S MCCB 400A

Price Range 50.00 - 500.00 INR / Piece

Minimum Order Quantity : 100 Pieces

Rated Current : 400A

Rated Voltage : 415V AC

Weight : 4.5 kg

Rated Short Circuit Making Current : 72 kA

MERLIN GERIN (NKF250D) 250 AMP MCCB

MERLIN GERIN (NKF250D) 250 AMP MCCB

Price Range 50.00 - 500.00 INR / Piece

Minimum Order Quantity : 100 Pieces

Rated Current : 250 Amp

Rated Voltage : 415V AC

Weight : Approx. 3.5 kg

Rated Short Circuit Making Current : 36 kA

C&S MCCB 630A

C&S MCCB 630A

Price Range 50.00 - 500.00 INR / Piece

Minimum Order Quantity : 100 Pieces

Rated Current : 630A

Rated Voltage : 415V AC

Weight : 7 Kg

Rated Short Circuit Making Current : 100 kA



Back to top